Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add filters








Type of study
Language
Year range
1.
Journal of Laboratory Medicine and Quality Assurance ; : 95-101, 2010.
Article in Korean | WPRIM | ID: wpr-10374

ABSTRACT

BACKGROUND: We report here the results of surveys for external quality assessment of blood bank tests performed in 2009. METHODS: Survey specimens were sent three times to 488, 491 and 490 participant institutes, and the response rates for the 1st, 2nd and 3rd trial were 97.7%, 98.0%, and 98.0%, respectively. Test items for the surveys were ABO grouping, Rh (D) typing, crossmatching, direct antiglobulin test, antibody screening and antibody identification test. RESULTS: The average accuracy rates of ABO grouping and Rh typing were 99.6-100% and 98.5-100%, respectively. In crossmatching test, the accuracy rates were 99.3-99.8% for the compatible samples, 92.7-100% for the incompatible samples, and 92.6-93.1% for the samples which could be detected as incompatible only by antiglobulin method. The accuracy rates of direct antiglobulin test were 98.5-100% for negative samples and 98.1-98.8% for positive samples. The correctresults were reported by 98.0-100% of the surveyed institutions for antibody screening test and 82.9-100% for antibody identification test. Nineteen institutions gave repeatedly incorrect answers for crossmatching test. Eight institutions out of them gave incorrect answers for all the test specimens sent out 3 times last year. CONCLUSIONS: The overall results of this survey were good, however, it is required that the institutions where the incorrect results were reported should perform corrective actions for quality improvement.


Subject(s)
Academies and Institutes , Blood Banks , Coombs Test , Korea , Mass Screening , Quality Improvement
2.
Journal of Laboratory Medicine and Quality Assurance ; : 99-104, 2009.
Article in Korean | WPRIM | ID: wpr-54348

ABSTRACT

We report here the results of surveys for external quality assessment of blood bank tests performed in 2008. Survey specimens were sent three times to 460, 470 and 473 participant institutes, and the response rates for the 1st, 2nd and 3rd trial were 97.6%, 97.7%, and 97.7%, respectively. Test items for the surveys were ABO grouping, Rh (D) typing, crossmatching, direct antiglobulin test, antibody screening and antibody identification test. The average accuracy rates of ABO grouping and Rh typing were 100% and 98.3-100%, respectively. In crossmatching test, the accuracy rates were 97.5-99.7% for the compatible samples, 92.4-99.2% for the incompatible samples, and 88.2-98.9% for the samples which could be detected as incompatible only by antiglobulin method. The accuracy rates of direct antiglobulin test were 98.4-99.7% for negative samples and 93.4-99.7% for positive samples. The correct results were reported by 99.6-100% of the surveyed institutions for antibody screening test and 98.2-100% for antibody identification test. Twenty-three institutions gave repeatedly incorrect answers for crossmatching test. Ten institutions out of them gave incorrect answers for all the test specimens sent out 3 times last year.


Subject(s)
Academies and Institutes , Blood Banks , Coombs Test , Korea , Mass Screening
3.
Journal of Laboratory Medicine and Quality Assurance ; : 103-109, 2008.
Article in Korean | WPRIM | ID: wpr-130608

ABSTRACT

We report here the results of external quality assessment of blood bank tests performed in 2007. Survey specimens were sent three times to 448, 450, and 455 participant institutes, and the response rates were 99.3%, 97.3%, and 98.0%, respectively. Test items for the surveys were ABO grouping, Rh(D) typing, crossmatching, direct antiglobulin test, antibody screening and identification test. The average accuracy rates of ABO grouping and Rh typing were in the range of 99.5-100% and 98.9-100%, respectively. In crossmatching test, the accuracy rates were 96.0-97.1% for the compatible samples, 89.6-92.4% for the incompatible samples, and 89.6-92.4% for the samples which could be detected as incompatible only by antiglobulin method. The accuracy rates of direct antiglobulin test were 98.0-99.7% for negative samples and 96.3-99.0% for positive samples. The correct results were reported by 95.7-100% of the surveyed institutions for antibody screening test and 98.2-100% for identification test. Fifteen institutions gave repeatedly incorrect answers for crossmatching. Five institutions out of them gave incorrect answers for all the test specimens sent out 3 times last year.


Subject(s)
Academies and Institutes , Blood Banks , Coombs Test , Korea , Mass Screening
4.
Journal of Laboratory Medicine and Quality Assurance ; : 103-109, 2008.
Article in Korean | WPRIM | ID: wpr-130601

ABSTRACT

We report here the results of external quality assessment of blood bank tests performed in 2007. Survey specimens were sent three times to 448, 450, and 455 participant institutes, and the response rates were 99.3%, 97.3%, and 98.0%, respectively. Test items for the surveys were ABO grouping, Rh(D) typing, crossmatching, direct antiglobulin test, antibody screening and identification test. The average accuracy rates of ABO grouping and Rh typing were in the range of 99.5-100% and 98.9-100%, respectively. In crossmatching test, the accuracy rates were 96.0-97.1% for the compatible samples, 89.6-92.4% for the incompatible samples, and 89.6-92.4% for the samples which could be detected as incompatible only by antiglobulin method. The accuracy rates of direct antiglobulin test were 98.0-99.7% for negative samples and 96.3-99.0% for positive samples. The correct results were reported by 95.7-100% of the surveyed institutions for antibody screening test and 98.2-100% for identification test. Fifteen institutions gave repeatedly incorrect answers for crossmatching. Five institutions out of them gave incorrect answers for all the test specimens sent out 3 times last year.


Subject(s)
Academies and Institutes , Blood Banks , Coombs Test , Korea , Mass Screening
5.
Journal of Laboratory Medicine and Quality Assurance ; : 91-97, 2006.
Article in Korean | WPRIM | ID: wpr-98182

ABSTRACT

We report here the results of surveys for external quality assessment of blood bank tests performed in 2005. Response rates for the 1st, 2nd and 3rd trial were 97.0%, 96.8%, and 97.1% respectively. Test items for the surveys were ABO grouping, Rh(D) typing, crossmatching, direct antiglobulin test, antibody screening and identification test. The average accuracy rates of ABO grouping and Rh typing were in the range of 99.5-100% and 99.7-100% respectively. In crossmatching test, the accuracy rates were 94.3-98.2% for the compatible samples, 88.5-92.9% for the incompatible samples, and 88.5-92.9% for the samples which could be detected as incompatible only by antiglobulin method. The accuracy rates of direct antiglobulin test were 98.9-99.3% for negative samples and 89.2-96.9% for positive samples. The correct results were reported by 98.3-100% of the surveyed institutions for antibody screening test and 98.9-100% for identification test. Seventeen institutions gave repeatedly incorrect answers for crossmatching. Thirteen institutions out of them gave incorrect answers for all the test specimens sent out 3 times last year.


Subject(s)
Blood Banks , Coombs Test , Korea , Mass Screening
6.
Journal of Laboratory Medicine and Quality Assurance ; : 85-90, 2005.
Article in Korean | WPRIM | ID: wpr-68694

ABSTRACT

We report here the results of surveys for external quality assessment of blood bank tests performed in 2004. Response rates for the 1st, 2nd and 3rd trial were 96.4%, 96.8%, and 96.8%, respectively. Test items for the surveys were ABO grouping, Rh(D) typing, crossmatching, direct antiglobulin test, antibody screening and identification test. The average accuracy rates of ABO grouping and Rh typing were in the range of 100% and 100%, respectively. In crossmatching test, the accuracy rates were 96.2-97.8% for the compatible samples, 75.5-90.6% for the incompatible samples, and 75.5-90.6% for the samples which could be detected as incompatible only by antiglobulin method. The accuracy rates of direct antiglobulin test were 98.8-100% for negative samples and 87.3-98.8% for positive samples. The correct results were reported by 98.8-100% of the surveyed institutions for antibody screening test and 100% for identification test. Forty six institutions gave repeatedly incorrect answers for crossmatching. Nine institutions out of them gave incorrect answers for all the test specimens sent out 3 times last year.


Subject(s)
Blood Banks , Coombs Test , Korea , Mass Screening
7.
Journal of Laboratory Medicine and Quality Assurance ; : 97-102, 2004.
Article in Korean | WPRIM | ID: wpr-60356

ABSTRACT

We report here the results of surveys for external quality assessment of blood bank tests performed in 2003. Response rates for the 1st, 2nd and 3rd trial were 93.1%, 91.7%, and 90.1%, respectively. Test items for the surveys were ABO grouping, Rh(D) typing, crossmatching, direct antiglobulin test, antibody screening and identification test. The average accuracy rates of ABO grouping and Rh typing were in the range of 99.7-100% and 99.7-100%, respectively. In crossmatching test, the accuracy rates were 97.4-100% for the compatible samples, 83.4-100% for the incompatible samples, 87.2-92.4% for the samples which were incompatible in albumin phase, and 83.4-88.8% for the samples which could be detected as incompatible only by antiglobulin method. The accuracy rates of direct antiglobulin test were 97.9-99.6% for negative samples and 93.8-95.0% for positive samples. The correct results were reported from 95.9-100% of the surveyed institutions for antibody screening test and 98.8-100% for identification test. Forty six institutions gave repeatedly incorrect answers for crossmatching. Nine out of 46 institutions gave incorrect answers for all the test specimens sent out 3 times last year.


Subject(s)
Blood Banks , Coombs Test , Korea , Mass Screening
8.
Journal of Laboratory Medicine and Quality Assurance ; : 99-104, 2003.
Article in Korean | WPRIM | ID: wpr-219211

ABSTRACT

We report here the results of surveys for external quality assessment of blood bank tests performed in 2002. Response rates for the 1st, 2nd and 3rd trial were 91.0%, 91.6%, and 91.8%, respectively. Test items for the surveys were ABO grouping, Rh(D) typing, crossmatching, direct antiglobulin test, antibody screening and identification test. The average accuracy rates of ABO grouping and Rh typing were in the range of 99.4-100% and 97.4-100%, respectively. In crossmatching test, the accuracy rates were 92.5-98.3% for the compatible samples, 73.7-99.7% for the incompatible samples, 88.0% for the samples which were incompatible in albumin phase, and 73.7% for the samples which could be detected as incompatible only by antiglobulin method. The accuracy rates of direct antiglobulin test were 96.3-98.4% for negative samples and 95.9-97.0% for positive samples. The correct results were reported by 98.6-100% of the surveyed institutions for antibody screening test and 100% for identification test. Forty six institutions gave repeatedly incorrect answers for crossmatching. Nine institutions out of them gave incorrect answers for all the test specimens sent out 3 times last year.


Subject(s)
Blood Banks , Coombs Test , Korea , Mass Screening
9.
Journal of the Korean Pediatric Society ; : 1501-1508, 1992.
Article in Korean | WPRIM | ID: wpr-7252

ABSTRACT

No abstract available.


Subject(s)
Humans , Hemophilia A
10.
Yeungnam University Journal of Medicine ; : 32-41, 1991.
Article in Korean | WPRIM | ID: wpr-93944

ABSTRACT

This study was made to investigate the effect of adenoidectomy on dentofacial skeleton in naso-respiratory dysfunction children. The clinical material compromised the 24 children in a previous study who had naso-respiratory dysfunction and 24 children who were the nasal breathing with normal occlusion. The cephalograms were taken at the initial examination and 1 year later for the control group and experimental group the paired sample statistical analysis was performed. The results were as follows. 1. In cranial base variable, difference between two groups were not statistically significant. 2. In craniofacial variables, experimental group showed brachyfacial pattern but control groups didn't show significant growth pattern. 3. In maxillary variables, experimental group showed flattening the plane. 4. In mandibular variables, experimental group showed the decrease of mandibular plane angle and gonial angle. 5. In facial height variables, experimental group showed horizontal growth rotation.


Subject(s)
Child , Humans , Adenoidectomy , Adenoids , Respiration , Skeleton , Skull Base
SELECTION OF CITATIONS
SEARCH DETAIL